1、This valve is control the hole straight with a moving valve, can be internal control or external control. According to different combinations produce different functional low-pressure relief valve used, sequence valves and unloading valves.
2、HCG (HCT) with a one-way valve, the oil flow from the secondary pressure of the oil port free flow of a pressure oil port, according to different combinations produce different capabilities to contend valves, one-way valve in order.
3、Installation dimensions in line with ISO 5781 standards.
4、Be widely used in hydraulic machines, injection molding machines and hydraulic circuits have two or more dedicated machines divided loop.
|
Further Information
How to order:
H |
B |
G |
-03 |
C |
4 |
Series number |
Pressure adj.
Range |
Type of
connection |
Valve size |
With check valve |
Type of valve |
H |
A:10-70kgf/cm2
B:35-140kgf/cm2
C:70-250kgf/cm2 |
G:sub plate
type
T:Thread type |
03:10(3/8")
06:25(3/4")
10:32(11/4") |
None:With check valve |
As table |
Specification:
Model |
Rated flow ℓ/min |
Max.operating
pressure mpa |
Pressure adj.
Range mpa |
Weight kg |
Sub plate
type |
Thread type |
Sub plate
type |
Thread type |
HG-03 |
HT-03 |
50 |
25 |
A:1.8-3.5 B:3.5-7 C:7-14 H:7-21 |
4.0 |
3.7 |
HCG-03 |
HCT-03 |
50 |
25 |
4.8 |
4.1 |
HG-06 |
HT-06 |
125 |
25 |
6.1 |
6.2 |
HCG-06 |
HCT-06 |
125 |
25 |
7.4 |
7.8 |
HG-10 |
HT-10 |
250 |
25 |
11.0 |
12.0 |
HCG-10 |
HCT-10 |
250 |
25 |
13.8 |
13.8 |
Dimension figure:
|