Index > Electro-Hydraulic Proportional Pilot Relief Valves > EDG
Electro-Hydraulic Proportional Pilot Relief Valves
1、By a small DC proportional solenoid relief valve and direct-action component, responsive, high precision, linear degree of good.
2、Level of pressure changes applied to more automated systems.
3、Widely used in injection molding machines and other high-performance machines among.
 Further Information
How to order:
EDG -01 -H -
Series number Valve size Pressure
adj,range mpa

Safty valve

EDG 01: 3 B: 0.5∼7.0
C: 1.0∼16
H: 1.2∼24.5

-:With
t:without

Specification:
Model

flow ℓ/min

Pressure
adj.range MPa
Rated current ma Coil resistance Hysteresis Repeatabiliy Weight kg
EDG-01 0.3-2 B: 0.5∼7.0
C: 1.0∼16
H: 1.2∼24.5
B: 800
C: 900
H: 950
10 <3% 1% 2
Dimension figure:
Use announcements:
1、Installation: Just ensure that vents upward, exhaust port location Ke Yi need to be changed arbitrarily.
2、To exclude the air: In order to control stability, we should all rows off the air and oil filled with electromagnetic valve core. In order to row out to be a gradual release of air proportional valve side vents. The location of the exhaust port can be changed, so that the air can be easily discharged from the valve. To change the location of the exhaust port when the solenoid connector can be rotated until the exhaust port to reach the required position.
3、Return pipe and vent pipe: Back to the pipeline back-pressure and back pressure a direct impact on oil spills minimum pressure or flow regulation Fazhu regulate the operation of power spool. Therefore, not the return pipe and other pipe connections, because of the direct connection with the tank, so that the low back pressure as much as possible. In addition the need to ensure return of oil and vent tubing immersed in the oil in the end.
4、Hysteresis and repeatability values atlanto: In the specifications described in each of a control valve hysteresis and repeatability values measured under the following conditions. A, hysteresis value is provided by the company to use Asada power amplifier of the measured; B, repeatability values are under the same conditions provided by the company to use Asada power amplifier of the value of the measured body.
5、Manual adjustment screws: initial sub-conditioned or because of electrical problem prevents valve failure, and so there is no input current when the rotating manual adjustment screws on the pressure and flow valves temporary set. However, in normal circumstances, the screws should maintain its original position.
Home | About Us | Privacy | Industry Link | Site Map | Feedback
Service time:From Mon to Sat:8:30~17:30    
Hotline:0086-21-67247466  86-13857458307 Fax:0086-21-67247499  
MSN:jackshawpw@hotmail.com  Skype:Jackbedra  EMAIL:service@kuking.tw  
Copyright(C) 2000-2009 Shanghai KukingMachinery Co.,Ltd    
Kuking Group Co.,LTD All Rights Reserved     
    
沪ICP备07006861号