Index > Air Conditioner > ACE
Air Conditioner
1、ACE aluminum air cooler uses the world's advanced synchronization stratified flow cooling technology, the use of thin-walled tube-like heat wave among the special-cum-film, greatly increased the area of oil and exposed to the air, so that the full release of high-temperature heat the oil and reduce the back pressure generation.
2、ACE aluminum air cooler to minimize the volume to maximize the heat exchange efficiency.
3、Traditional cooler design of the use of round tubing, making the flow of oil into the U-line, increasing back pressure. To reduce the area exposed to the air, thereby reducing the heat exchange rate.
4、Cooler is made from aluminum maximum working pressure of 2.0MPa, small size, light weight, easy to install, simple maintenance
Scope: Work pressure 1MPa, flow of 10 ℓ / min-200 ℓ / min, a variable pump for cooling the oil spill.
 Further Information
How to order:
ACE 2 M1 01 40
Series number Model FAN

Fan voltage

Fan power

ACE 1
2
3
4
5
6
7
8
1:1个 Motor
2:2个 Motor
01-110VAC
02-02-220VAC
03-03-12VAC
04-24VAC
ACE1: 32
ACE2: 40
ACE3: 65
ACE4: 65
ACE5: 100
ACE6: 200
ACE7: 100
ACE8: 200
Specification:
Model Threaded Flow ℓ/min Work pressure mpa Max.operating pressure mpa Fan power
ACE1-M2 M18*1.5 10 2.0 2.5 30
ACE2-M2 M18*1.5 20 2.0 2.5 40
ACE3-M1 M18*1.5 25 2.0 2.5 65
ACE4-M1 M22*1.5 30 2.0 2.5 65
ACE5-M1 M27*1.5 55 2.0 2.5 100
ACE6-M1 M27*2 100 2.0 2.5 200
ACE7-M1 M33*2 120 2.0 2.5 100
ACE8-M1 M33*2 160 2.0 2.5 200
Dimension figure:
Use announcements:
Note: We provide quality products and excellent service, with four series of dozens of specifications. Products can be used for oil spills or to return to the oil cooling, with a variety of installation methods. Has also designed and manufactured according to user needs. .
Product series:
1、AF series: Working pressure 1MPa, flow rate 4 4ℓ/ min, 6 4ℓ/ min, a variable pump for cooling the oil spill.
2、AW series: Working pressure 1MPa,flow rate 20ℓ/min,a variable pump for cooling the oil spill.
3、AH series: Working pressure 2MPa,flow rate 30ℓ/min-300ℓ/min,a variable pump for cooling the oil spill.
4、ACE series: Working pressure 1MPa,flow rate10ℓ/min-200ℓ/min,a variable pump for cooling the oil spill.
Note: 1, coolers should be installed firmly, the installation position to avoid vibration and shock, ensuring freedom of inlet and exhaust flow, and to prevent inhalation of the ministries components have been heated air.
2、Cooler use, you must install limit pressure bypass, in order to avoid excessive pressure drop generation, to prevent the impact force generated at startup may cause excessive damage.
3、Cooler export connector, six months, please be careful, we must use tools for gripping the oil out of the radiator mouth, so as to avoid heat distortion.
4、Coolers should be kept clean at least once a week cleaning radiator.
RemarksAir Conditioner,The related model:ACE1-M2,ACE2-M2,ACE3-M1,ACE4-M1,ACE5-M1 and so on
Home | About Us | Privacy | Industry Link | Site Map | Feedback
Service time:From Mon to Sat:8:30~17:30    
Hotline:0086-21-67247466  86-13857458307 Fax:0086-21-67247499  
MSN:jackshawpw@hotmail.com  Skype:Jackbedra  EMAIL:service@kuking.tw  
Copyright(C) 2000-2009 Shanghai KukingMachinery Co.,Ltd    
Kuking Group Co.,LTD All Rights Reserved     
    
沪ICP备07006861号